2019年3月20日星期三

Scania VCI-3 VCI3 Scanner Wifi Wireless Diagnostic Tool Online

V2.21 Scania VCI-3 VCI3 Scanner Wifi Wireless Diagnostic Tool Online
SCANIA VCI3 Highlights:
1. Scania VCI3 is designed to support all Scania diagnostic systems based on CAN network, it’s a extremely fast yet very compact diagnostic tool.
2. One of the most interesting new features that can be found in Scania VCI3 is a Wifi wireless connection (also there is a USB connector for wired connection).
3. From now you can work without wired connection to your truck, just forget these problems like damaged data cables and other disadvantages of wired connections.
4. Software support for Scania VCI3 appeared in Scania SDP3 2.18 version so if you want to use this tool you need this version of SDP3 or later versions of this software.
5. The device is designed for full service trucks, buses and other heavy vehicles, which produces the corporation SCANIA. Adapter works in conjunction with software SDP-3.
6. The adapter does not work with trucks and engines manufactured before 2004.
7. The main feature of VCI-3 – Work through a high-speed WI-FI connection. Also in the device has a USB port.
Attention: You need to install the V2.21 Scania VCI-3 Software on window7 32bit.

2019年3月12日星期二

(Free Download )Nissan consult 3 plus V72.13 – ECU programming works

Nissan Consult 3 Plus features:
– Update support ECU programming without immobiliser card (old version does not support programming)
– Perform diagnosis and programming till year 2016.
Nissan Consult 3 Plus works on:
1.Nissan Consult-3 plus (Nissan consult 3+) work for all nissan car, infiniti car and nissan gtr car to 2016.
2.Nissan Consult-3 plus work with obd-16 connector for the new kind of car, work with 14 pin connector for the old Nissan.
3.Nissan Consult-3 plus support Nissan car electronic system diagnostic
4.Nissan Consult-3 plus support Nissan electromobiles such as Leaf.
5.Nissan Consult-3 plus support all Renault diagnosis.
6.Can calculate the security code for the new cars till year 2016 with NISSAN Password.
Note: Nissan Consult iii Plus support key programming as well,but you need to buy immobiliser security card to work with.
Cnautotool.com Nissan Consult 3 Plus V72.13 installation:
1.Click Consult-iii-* setup.exe
2.Step 2: Just show Nissan Consult III Setup Wizard
3.Step 3: Choose the installation path of Consult III
4.Step 4: click Install Consult III software
5.Step 5: wait for the Installshield Wizar
6.Step 6: Choose: accept the terms of Nissan Consult License agreement
7.Step 7: Choose North America market(NAM), click next
8.Step 8: Choose North America
9.Step 9: choose U.S.A
10.Step 10: you also can choose others language Step 11: the installation of Consult – III software succeeded
The installation guide of Nissan Consult III USB drive Connect the Consult III firmware with your pc by USB cables, and connect the Consult III hardware with your car via OBD-II 16pin diagnostic plug, supply 12V power to Consult III firmware.
1.Step 1: Found New hardware( Nissan Consult III) Wizard, choose “Yes, this time only”
2.Step 2: Choose Install the Consult III software automatically
3.Step 3 Choose JCI-iB-Alliance vehicle interface, just click next
4.Step 4: just click finish, completing Consult III hardware drive installation
How to Crack Nissan Consult III software, and configure Consult III software
1.Step 1: Open Consult III software on desktop
2.Step 2: perhaps show these error: there are no registered VI/MI, please contact your administrator, just ignore, click “OK”
3.Step 3: click “SUB” button
4.Step 4: click Administrator setting
5.Step 5: input Consult III Password — nissanconsult3
6.Step 6: Choose VIMI registration
7.Step 7: Input Consult III VI serial number: 926573, and click: set
8.Step 8: Click the home button
9.Step 9: then click: “Connect” button
10.Step 10: the Consult III will found hardware, show: checking the firmware version
11.Step 11: choose the Function of Consult III software, just enjoy it

2019年3月6日星期三

What the Autel ms908s Pro can do for you

 Wireless printing may be tough to get your head about since it requires your MaxiSys to communicate together with your Computer via a network. This sounds a lot more difficult than it truly is.
Difficulty: Average. Expertise of installing a conventional printer is going to be a bonus.
Time: 10 – 20 mins primarily based on online connection and updates.
What to prepare:
* An active Internet connection on your Computer.
* A Wireless Network – like a broadband router.
* A Windows Primarily based Computer with full administrative Rights (be capable of run programs in administrative mode)
* To make certain the Pc is connected towards the network either wirelessly by way of Ethernet.
* Your Computer to possess Adobe Reader installed.
* The MaxiSys Pc Suite CD (positioned inside the box).
Firstly, possess a appear in the following diagram:
ms908p-1
So how does this diagram operate? Initial you need to set up the MaxiSys Print Driver in your Pc. Then you definitely connect your MaxiSys towards the identical network. Then, after you send a Print command from your MaxiSys, the MaxiSys will search the network for PCs that have the print driver installed. The MaxiSys (through being connected towards the similar network as your Computer) sends the information for the Computer, which in turn prints the data. Consequently, all the following have to be connected for the Exact same network and turned on;
* Your MaxiSys Tablet
* Your Pc
* Your Printer
After you have carried out this, stick to the measures below to set up the Print Driver on your Pc.
* Spot the Maxisys Pc Suite CD into your CD Drive. The software program might load automatically, but if not, Click Commence and after that My Laptop.
* You’ll want to now see a Orange Folder listed exactly where your CD drive usually is; this really is the Autel application CD. Double click to open this up. Inside this folder you must see an icon calledAutorun.exe. Click This. The welcome screen of the Computer suite really should now boot
* Around the Pc Suite screen, pick which Bluetooth Interface you’ve got (at time of going to publish, just about all UK users may have the black Bluetooth VCI unit, displayed on the appropriate) by clicking The installation will now begin.
* During installation you may be prompted to Set up Drivers or if you have a firewall, to let the computer software particular security preferences. This can be since the computer software is communicating together with your network. You need to accept these preferences or the computer software is going to be blocked and printing won’t work.
* As soon as installation has finished, you will need to open the MaxiSys Printer. To perform this click Startthen All Applications. Now scroll by means of your applications till you come across MaxiSys Computer Suite. Inside this folder you’ll discover MaxiSys Printer. Click on this Item.
* The Printer Driver will open and you will see a printer icon within the bottom suitable of your Computer, next towards the Time and Date. The Printer Driver is now installed.
* You might be prompted to execute an update (for example in the demonstration video above), in that case its a great concept to help keep the software program up to date. Bear in mind to constantly permit firewall preferences or new Autel drivers to become installed.
For those who have performed all the actions above and are nevertheless having issues, check the following:
* Does your Computer have an active world-wide-web connection?
* Does your Pc have complete administrative rights?
* Does yourMaxiSys have an active online connection? Are you able to load a web page in the tablets internet browser?
* Will be the MaxiSys printer icon loaded? Verify that the icon is being displayed in your system tray, next towards the Date and Time.
* Did you permit the right settings on your Firewall/Anti-virus if prompted?
* Do you’ve got Adobe Reader installed? Click hereto download the and install the latest version.

MB Star C6 Benz Diagnostic Tool with DOIP&AUDIO Function

VXDIAG MB SD Connect C6 MB Star C6 Benz Diagnostic Tool with DOIP&AUDIO Function
VXDIAG For XENTRY Diagnosis VCI is the latest interface for For Mercedes & SMART vehicles can replace Star C4/C5. VXDIAG For XENTRY Diagnosis VCI acts as a Pass-through Interface, also called Star C6, For Benz C6 multiplexer to provide complete communication between a vehicle and the VXDIAG For XENTRY software loaded on a PC.
VXDIAG MB SD Connect C6 XENTRY Diagnosis VCI Overview:
Compatible Software: XENTRY/Das Software
Support Vehicle: Mercede For Benz & Smart vehicles
DoIP: Support DoIP
Functions: Star Diagnostic & programming (SCN Coding)
XENTRY Software Show:
3-1
3-2
3-3
3-4
XENTRY Diagnosis VCI Summary:
The new VXDIAG For XENTRY Diagnosis VCI (Vehicle Communication Interface) multiplexer serves as the interface to the vehicle when performing diagnosis and repairs, and programming electric and electronic on-board vehicle systems.
The VXDIAG For XENTRY Diagnosis VCI does not have its own PC core, battery, fan, or display. It is operated using the VXDIAG For XENTRY Diagnosis Pad via WLAN or a USB cable connection.
3-5
3-6
3-7

2019年3月5日星期二

Consult-3 Plus for Nissan is the newest Nissan diagnostic tool

Nissan Consult 3 Plus for Nissan is the newest Nissan diagnostic tool.
1. Nissan Consult III Plus supports Nissan 2016 MY LEAF Quest and Murano Cross Cabriolet,
2.super racing MY GT-R and 2012 of NV and 2012 MY Infiniti M and M Hybrid from 2011/12.
3.Consult-3 Plus for Nissan= Consult-3 + Consult-2
Consult-3 Plus for Nissan Consult 3 V61.10 diagnostic tool for Nissan
Consult-3 Plus for Nissan= Consult-3 + Consult-2
Software Version: V61.10
C3+ GTR software V20.11
This Consult-3 Plus work for 2016 Nissan
Support Multi-Languages: English, French, German, Portuguese, Italian, Japanese, Finnish, Greek, Russian, Spanish, Turkish, TChinese(Simplified), Chinese(Traditional)
Communication Mode: USB 2.0 / Bluetooth
OS Requirement: Work with Windows XP,WIN7 WIN8 WIN10
Support Electronic control module Programming,If you want to key programming, please buy the Security Card for Immobilizer
V61.10 Software Download: https://mega.nz/#!aUR3BaxB!ZL3WccsZn–wG8xIirSzgqlZiEkgyxDRen9MrugEr-w
Consult 3 Plus Function:
Consult-3 Plus for Nissan can support all the models of the Nissan and Infiniti from 1996 up till now, with all Consult II & III functions .
And consult III plus can calcaulate the password for the new cars till year 2016 with NISSAN Password.
1. Consult-3 plus (consult 3+) work for all nissan car , infiniti car and for nissan gtr car to 2016.
2. Consult-3 plus work with obd-16 connector for the new kind of car, work with 14 pin connector for the old kind of car.
3. Consult-3 plus support for nissan car electrolic system diagnostic.
4. Consult-3 plus support for nissan electromobiles such as Leaf.
5. Consult-3 plus support all Renault.
Cnautotool.com Conslu-3 for Nissan Functions:
1. Scantool Diagnostics:for all Nissan,Infiniti,GTR
2. Immobi and Smart key:for all Nissan,Infiniti,GTR
3. Nissan GTR: for Nissan GTR Diagbostics and Immobi
4. Electromobiles car:for Nissan Electromobiles car Diagbostics and Immobi

Cat Service Information System (SIS)

Do you want to stay on top of your repair and maintenance costs? Use the same tool that Caterpillar and Cat? Dealers use: Cat ET Service Information System (SIS). SIS is available by subscription via the Web, Network or DVD. CAT SIS covers every Cat product from 1977 through today. With SIS, you get access to 1.5 million part numbers, 2 million graphics and thousands of parts and service documents.
Using SIS provides fast searches, keeps you up-to-date with the latest information, eliminates outdated information in print and makes it easier to order parts, even after normal business hours. Make Cat SIS your single safe source for Cat parts and service information. Call your local Cat dealer for more on Web, Network and DVD subscriptions.
Cat Service Information System (SIS)
Improve Efficiency, Minimize Downtime
* Interactive Schematics
* 2D Hotpointed Graphics
* Streamline repair and maintenance operations with troubleshooting,
diagnostic and safety information
* Find exactly what you need with fast, efficient keyword searches
* Get the latest information with automatic updating
* View three decades worth of information on every Cat product
* Eliminate lost, missing and out-of-date paper manuals
* Take information into the field with a DVD subscription
* Rely on one safe source for parts and service information
Heavy Duty Truck diagnostic Scanner Cat SIS DVD recommended system requirements:
* 2.0 GHz Pentium-compatible processor
* 2GB of RAM
* 9-16+ GB of Free Hard Drive Space available through 2011 to allow for growth in graphics
* Optional file transfer device (such as a 3.5” disk drive or USB port and compatible Jump-drive)
* Third generation DVD drive capable of reading dual layer DVDs
* Monitor capability of supporting 1024 x 768 resolution and Open GL supported Graphics Card (Recommend 128MB+ RAM)
* Pointing device, built-in or external
* Hewlett Packard LaserJet V or compatible printer
* Microsoft Windows (XP, Vista and Windows 7)
* Microsoft Internet Explorer version 7.0 or 8.0 (must support Java Script and
Cat Dealers define worldclass product support. www.cnautotool.com offer you the right parts and service solutions, when and where you need them. The Cat dealer network of highly trained experts keeps your entire fleet up and running to maximize your equipment investment.

2019年3月4日星期一

Consult-3 Plus for Nissan is the newest Nissan diagnostic tool

Nissan Consult 3 Plus for Nissan is the newest Nissan diagnostic tool.
1. Nissan Consult III Plus supports Nissan 2016 MY LEAF Quest and Murano Cross Cabriolet,
2.super racing MY GT-R and 2012 of NV and 2012 MY Infiniti M and M Hybrid from 2011/12.
3.Consult-3 Plus for Nissan= Consult-3 + Consult-2
Consult-3 Plus for Nissan Consult 3 V61.10 diagnostic tool for Nissan
Consult-3 Plus for Nissan= Consult-3 + Consult-2
Software Version: V61.10
C3+ GTR software V20.11
This Consult-3 Plus work for 2016 Nissan
Support Multi-Languages: English, French, German, Portuguese, Italian, Japanese, Finnish, Greek, Russian, Spanish, Turkish, TChinese(Simplified), Chinese(Traditional)
Communication Mode: USB 2.0 / Bluetooth
OS Requirement: Work with Windows XP,WIN7 WIN8 WIN10
Support Electronic control module Programming,If you want to key programming, please buy the Security Card for Immobilizer
V61.10 Software Download: https://mega.nz/#!aUR3BaxB!ZL3WccsZn–wG8xIirSzgqlZiEkgyxDRen9MrugEr-w
Consult 3 Plus Function:
Consult-3 Plus for Nissan can support all the models of the Nissan and Infiniti from 1996 up till now, with all Consult II & III functions .
And consult III plus can calcaulate the password for the new cars till year 2016 with NISSAN Password.
1. Consult-3 plus (consult 3+) work for all nissan car , infiniti car and for nissan gtr car to 2016.
2. Consult-3 plus work with obd-16 connector for the new kind of car, work with 14 pin connector for the old kind of car.
3. Consult-3 plus support for nissan car electrolic system diagnostic.
4. Consult-3 plus support for nissan electromobiles such as Leaf.
5. Consult-3 plus support all Renault.
Cnautotool.com Conslu-3 for Nissan Functions:
1. Scantool Diagnostics:for all Nissan,Infiniti,GTR
2. Immobi and Smart key:for all Nissan,Infiniti,GTR
3. Nissan GTR: for Nissan GTR Diagbostics and Immobi
4. Electromobiles car:for Nissan Electromobiles car Diagbostics and Immobi

2019年3月2日星期六

How to Do MaxiScope Firmware Update for Autel Maxisys tool

Autel MaxiScope Automotive Oscilloscope Basic Kit Works with Autel Maxisys MS905 MS906BT MS906TS MS908 MS908P Tool .
The operating software of the MaxiScope is continuously being developed, and the update package can be downloaded free from the MaxiScope product webpage on Autel’s website: http://www.autel.com.

How to update the MaxiScope firmware ?
1.Install the CD provided with the MaxiScope tool kit into the CD-ROM of the computer. The driver installation wizard will load momentarily. 2. Click on Next on the welcome page.
3.Click the Browse button, and select a destination folder to install the program, and click Next to continue. Or directly click Next to continue without changing the default installation folder.
4. Click Install and the Setup.exe program will be installed onto the computer.
5. After the installation is completed, connect the MaxiScope to the computer using the USB cable provided by the tool kit.
6. Locate and double click the MaxiScope Update icon on desktop, and the Firmware Update window will pop up onscreen.
7. Click on Select File to locate the newly downloaded firmware update package.
8. Click on the dropdown menu icon by the Set Language option at the top right of the window to select a desired language.
9. Click on Update to start updating.
If you have any request for Autel Maxisys tool , welcome to contact us on www.cnautotool.com , we will offer discount price for you .
Thank you

2019年2月25日星期一

Why we buy Autel Maxisys CV Heavy Duty Diagnostic Scan Tool

The complete MaxiSYS CV tool kit comes with the latest compact size J2534 MazxiFlash Elite . Features a built-in bluetooth VCI and performs pass-thru programming functions . The software support update online free one year and SAE J2534-2 compatible



Autel Maxisys CV is good heavy duty truck diagnostic tool which supported the special functions as bellow :

DOC/DPF Replacement Reset
Fuel Pressure Adaptation Reset
Injector CEOM Reset
O2 Sensor Calibration
Injection Quantity Adjustment
DPF Regeneration
DSI System De-Aeration
MAF Sensor Calibration

Parameter Setting
Aftertreatment Maintenance
Aftertreatment Maintenance Filter Installation
Aftertreatment Particulate Matter Sensor Regeneration
Aftertreatment SCR Catalyst Cold Soak Override
Aftertreatment SCR System Health Monitor
Boost Calibration
Rack Sensor Calibration

Timing Calibration
Monitor Throttle Position Sensor
Extended Service Coverage
Injector Trim Calibration
Configuration
Custom Data
Maintenance Monitor

Autel Maxisys CV Supported vehicles :


Autel Maxisys CV Supported protocol
SAE J1939
SAE J1708
Manufacture-defined Protocol J1939
Manufacture-defined J1708
KWP/VPW/CDL/UDS-CAN

Autel Maxisys CV Basic Functions
ECU version
Read DTC
Clear DTC
Actual Value
Activation Test

Autel Maxisys CV Highlight : AutoVin ,Autoscan
Any more advantages for maxisys cv truck scanner , welcome to check our website www.cnautotool.com

2019年2月23日星期六

How to Solve GM MDI Interface no Connection Issues ?


We have customers who have the issues for GM MDI Interface no connection/communication . And if we met this issues , how to do next ?
* We should make sure that the MDI Manager software should be installed on the PC and the MDI must be powered up before you use it to communicate.
* MDI should be configured for wired ethernet or wireless communication. If the USB is available, the MDI will connect by using the USB and if not, the MDI will connect by using wired ethernet and if neither of them is available, the MDI will connect by using wireless.
* If the MDI can not communicate with the MDI, you should check the cables if they are securely attached to the MDI, if the MDI has completed its power up sequence, if the connector pins are clean and if the MDI Manager software is running.
Lets check the 4 situations in details as bellow :
1.  GM MDI USB Connection 
If you connect it with USB , you need to check the MDI USB connection is detected by windows. About the solutions, you can connect the MDI to the PC USB port and power up the MDI. Open the Network and Dial-up Connections Window from the Windows Control Panel. Then check for the device name ETAS USB Remote NDIS Network Device. If it is not running, check all USB ports on the PC and verify that the MDI is powered on. But what can we do if MDI fail to connect by USB interface ?
* Check USB cable connections.
* Check Firewall Settings on your PC.
* Verify a USB Hub is not being used (MDI has a fixed USB address).
* Verify that only one MDI is connected to your PC using USB.
* Verify the USB driver has been installed on the PC (look for device name ‘ETAS USB Remote NDIS Network Device’ under Network connections).
* Try connecting to other USB ports on the PC.
2. GM MDI Connection by Wireless Ethernet 
If you connect them by wireless ethernet, you should make sure that wireless communication is enabled and the IP configuration is properly set using the MDI Manager software. Then what you need to check is that the USB cable is not plugged in, the MDI is not being used via wired ethernet and the wireless card is properly seated in the MDI. You can contact your IT department and check that your PC is detecting the wireless access point and the correct security settings have been configured for the MDI. How to do if MDI fails to connect on Wireless interface?
* Check the wireless card is properly seated in the WiFi GM MDI.
* Confirm LEDs on the wireless card are lighted when the MDI is powered.
* Verify the MDI and PC are within range of the Access Point or Router.
* Verify that the PC is connected to the Access Point or Router.
* Verify signal strength of the wireless network from the PC.
* Check Firewall Settings on your PC
* USB connection takes precedence, unplug USB cable.
* Wired Ethernet connection takes precedence, unplug Ethernet cable.
* Connect to MDI using USB and run MDI Manager to verify the Wireless Settings are configured correctly.
* Wireless interface is enabled.
* AP settings configured for proper security (authentication, encryption).
* Signal Quality (fair, good, excellent) indicates connected to AP.
* The MDI, PC and AP are on the same subnet
* If using static IP, verify the IP Address and Subnet mask are correct (supplied by network administrator ).
3. GM MDI Connection by Wired Ethernet 
If you connect then by wired ethernet, you need to ensure that the wired ethernet communication is enabled and configured using the MDI Manager software. Then you should check that the USB cable is not plugged in and the MDI device detects wired ethernet activity by viewing the lights blinking on the wired ethernet port of the MDI. And also you can contact your local IT department and check that the MDI and the PC are on the same subnet. So how to do if MDI fails to connect on Wired Ethernet ?
* Check Ethernet cable connections.
* Check Firewall Settings on your PC.
* Verify the MDI and the PC are cabled into separate LAN connections on the same network.
* Verify that the PC is properly configured and can communicate on the network.
* USB connection takes precedence, unplug USB cable.
* Connect to MDI using USB and run MDI Manager to verify the Wired Ethernet Settings are configured correctly.
* Wired Ethernet interface is enabled.
* If using static IP, verify the IP Address and Subnet mask are correct (supplied by your network administrator).
4. GM MDI not Connection
When you have met the error ” not connected to MDI “, you should to refresh the GM MDI firmware , how to refresh , please check the bellow steps :
* Press this button and connect the power:

* Keep press this button and connect it to power, the power light will be on, wait about 10 seconds:

* When all light is on, then you can release the button, and it will enter firmware refresh status:

* Connect GM MDI with your PC via USB cable, prepare to refresh the firmware:

* Open “GM MDI Manager”, choose “Recover”:

Do you have any other issues ? Welcome to contact us directly